Octagonal shafts in the production hall
Standard range

Octagonal steel poles

Octagonal shafts formed from two press-braked halves for roads, junctions, logistics yards and area lighting — with reinforced door opening and base plate with anchor bolt set.

6–18mheight range
75–105mmtop size d1 (A/F)
130–375mmbase size d2 (A/F)
4 · 5mmwall thickness

Octagonal shafts in the production hall

Overview

Two halves, two seams

Each octagonal section is formed on the press brake from two trapezoidal halves and closed by two longitudinal welds — the same route that carries our polygonal high masts.

Standard range

6–14 m

6 to 14 m with 4 mm wall is the standard range, verified to EN 40-3 for each project site.

On request

15–18 m

15 to 18 m poles are built with 5 mm wall and a two-segment shaft; joint and base details are confirmed for each project.

Octagonal poles with flange plates · batch production
Octagonal poles with flange plates · batch production
HhLh1Rd1d2AB × CdoorKShaft sectionA/F — across flatsBase plate · planDEF × GSchematic, not to scale.

Construction

Shaft, door, base

Shaft
Two press-braked halves, two longitudinal seams
Heights
6–14 m standard · 15–18 m on request (5 mm wall, two-segment shaft)
Door
400 × 100 to 500 × 140 mm, 600 mm above ground · reinforced opening
Base
Base plate with four slotted holes · M18–M27 anchor bolt set
Steel
S235JR · S355J0 on request — EN 10025-2
Finish
Hot-dip galvanized to EN ISO 1461 at approved partner plants

The letters on the drawing are the column headings of the dimension tables below.

Dimensions

Standard sizes

Octagonal shafts with 4 mm wall for 6–14 m with long brackets, and 4–5 mm wall for 12–18 m with short brackets. Sizes d1 (top) and d2 (base) are measured across flats (A/F).

Octagonal poles 6–14 m with long bracket
PoleBracket arm
Hhd1 A/Fd2 A/Fth1LRØ × t
6,0005,0007513041,0001,00070060.3 × 2.90
8,0007,0007515641,0001,50070060.3 × 2.90
9,0008,0007515641,0001,50070060.3 × 2.90
10,0008,0007518042,0002,0001,00060.3 × 3.65
12,00010,0009025042,0002,5001,50060.3 × 3.65
14,00012,0009028542,0002,5001,50060.3 × 3.65

Dimensions in mm. H = overall height, h = shaft height, d1 / d2 = size across flats at the top and at the base, t = wall thickness, h1 / L / R = bracket height, outreach and bend radius, Ø × t = bracket tube.

Certified types

SR 10 and SR 13 to EN 40-5

Two octagonal column types are type-tested to EN 40 and covered by a certificate of constancy of performance issued by a notified body.

SR 10

EN 40-5
Height
10 m · one-piece octagonal shaft
Wall
4 mm · steel S235JR
Base plate
400 × 400 × 12 mm
Top
spigot Ø60.3 mm
Mass
approx. 164 kg (drawing)

SR 13

EN 40-5
Height
approx. 13 m · two segments, 600 mm slip joint
Wall
4 mm · steel S235JR
Base plate
495 × 495 × 15 mm
Top
spigot Ø88.9 mm
Mass
approx. 280 kg (drawing)

Configurations

Brackets, doors and bases

Poles are supplied complete where specified in the order — with door, fixings, base plate and anchor set matched to height and bracket.

Reinforced door opening

Doors

Reinforced openings, flush door with locking lever and Allen-key type lock, steel retaining chain.

Base plate with stiffeners

Bases

Base plates with stiffeners where required, anchor bolt sets with template.

Pole tops with spigots

Tops

Single-, double- and multi-arm brackets in Ø60.3 mm tube, or post-top spigots for top-mounted luminaires.

Configurations

  • Single-arm
  • Double-arm
  • Multi-arm 4 / 6
  • Post-top spigot
  • Base plate

Typical applications

  • Roads & motorways
  • Junctions & squares
  • Logistics & industrial yards
  • Area & floodlighting

Standard bracket arms

Armh1LRØ × t
1.0 / 1.01,0001,00070060.3 × 2.90
1.0 / 1.51,0001,50070060.3 × 2.90
2.0 / 2.02,0002,0001,00060.3 × 3.65
2.0 / 2.52,0002,5001,50060.3 × 3.65

Dimensions in mm. h1 = vertical height of the arm above the pole top; arm tip inclined 10°. Outreach is stated separately for each project; multi-arm brackets (4- and 6-way) on request.

Supplied as specified in the order

  • Inspection door with lock, chain and locating lug
  • Gear-tray fixing: 2 × 4 welded M10 nuts
  • Earthing lug inside the door opening
  • Base plate with slotted holes
  • Anchor bolt set with nuts, washers and template
  • Top spigot or bracket fixing, cap

Luminaires, gear trays, cables and foundations are not included unless agreed in the order.

Finish

Where specified in the order, poles and accessories are hot-dip galvanized to EN ISO 1461 at approved partner plants; threaded fasteners to EN ISO 10684. Ungalvanized supply and other coating systems to the client’s specification.

For your quotation

What we need for a quotation

Send the following information — we reply with a technical and commercial offer.

Product & quantity
pole type, number of pieces
Height & configuration
bracket type, outreach, post-top
Luminaires
number, mass and projected area
Site
country, location, wind basis or terrain
Base
base plate with anchors, or planted
Finish
hot-dip galvanizing, further systems
Delivery
destination, Incoterms, schedule
Documents
standards, calculations and certificates required

What happens next

  1. 01
    Review

    We check drawings, specifications, materials and quantities for manufacturability.

  2. 02
    Clarification

    Open technical points are raised and agreed in writing.

  3. 03
    Offer

    Technical and commercial offer with scope, exclusions and assumptions.

  4. 04
    Order

    Shop drawings for approval, then fabrication under our certified system.

Request a quote for this product
Chapter in the Master Catalogue 2026pages 22–27 · PDFProduct brochure: Octagonal Poles8 pages · PDF · 6.6 MB

Enquiry

Request a technical manufacturing review

Send drawings, loads and specifications — we review manufacturability before we quote.

Contact our office

Office · WhatsApp & Viber
+389 76 303 316

The buttons open a chat with our office in the app. Nothing is sent until you write a message and send it.

Office
+389 33 444 414
Sales · ATOM POLES
info@atompoles.eu
Company · ATOM STEEL
info@atomsteel.eu

This website works without tracking. You decide whether external media and measurement may be used. You can change this at any time through “Privacy settings” at the foot of every page.

Privacy policy